OPERATING CONTROLS AND INDICATORS TMS9000-2 OPERATOR MANUAL
3-132 Published 02-21-2019, Control # 611-05
Boom system setup display
Counterweight display
Required counterweight combination in tons (t) – for
displayed RCL code (Figure 3-198).
Telescoping Mode Number entry
The telescoping status or pinned boom configuration can be
selected from the RDM (RCL display). This is done by
selecting a Telescoping Mode Number (refer to 1,
Figure 3-199). There are 6 available pre-selected Mode
Numbers. Referring to Figure 3-199, the Telescoping Mode
Number is available to be selected since this option on the
display is selectable. However, this is only selectable after
the RCL has been initialized once (having previously used
the check-mark on this screen), the telescoping function has
been enabled, and the boom is fully retracted and locked.
With the Telescoping Mode Number option available, and
using Enter on this item on the screen, the up/down arrows
or jog dial can be used to select from 1 to 6. Figure 3-199
shows the appearance for Mode 1. It is seen that Mode 1 has
the requested pinned boom configuration of 100-100-100-
100-100. If this is the desired configuration, then Enter can
1
Main boom/auxiliary single-sheave boom top
(Figure 3-197)
2
Main boom with lattice extension, standard lattice
extension or heavy load lattice extension, which can
be angled.
FIGURE 3-197
8883-1
1
2
8882-2d