OPERATING PROCEDURES TMS9000-2 OPERATOR MANUAL
4-10
Published 02-21-2019, Control # 611-05
Switch off the heating system using the button (5,
Figure 4-2).
Press the button (6) for longer than 3 seconds.
The last set heating period, e.g. 27 minutes (Figure 4-10),
now flashes for 5 seconds in the display field.
Set the desired heating period with the buttons (6) and (7).
You can set a heating period of 10 to 120 minutes.
Wait for approx. 5 seconds until the current time is displayed.
A new heating period has now been set.
Switching the heating start on and off
To switch on an automatic heating start, you must retrieve
the corresponding storage location.
To retrieve a storage location, press the button (1,
Figure 4-7) once.
The display field flashes for 5 seconds and a storage location
is shown (e.g. 2) (Figure 4-11). The heating start at this
storage location is now switched on.
To switch on a different heating start, press the button (6)
repeatedly until the desired storage location is displayed.
This heating start is switched on as soon as the display stops
flashing.
To switch off the automatic heating start, press the button (6)
repeatedly until a storage location is no longer displayed.
Switching off
This section only describes how to switch off the heater
manually. If the heater is switched on automatically, it
switches off after the set heating period has elapsed, refer to
the procedure above.
To switch off, press the button (5, Figure 4-2) once. The
heater goes off immediately.
NOTE: If you turn off the ignition while the heater is in
operation, the heater will continue running for a
certain period. You can set this remaining time by
performing the following procedure.
Setting the remaining time
If the ignition is turned off with the heater turned on, the
heater will remain switched on for the remaining time.
Switch on the heating system using button (4, Figure 4-2).
Switch off the ignition.
The heating system will continue to run and the last set
remaining time will flash, e.g. 48 minutes (Figure 4-12).
Set the desired remaining heating period with the buttons (6,
Figure 4-2) and (7) in the flashing display. You can set a
remaining time of 1 to 120 minutes.
Wait for 5 seconds until the current time is displayed.
The remaining time is now set.
Air-conditioning system
You can use the air-conditioning system to cool and dry the
air in the superstructure cab when the engine is running.
Switching on
At the heating/air conditioning control panel:
Press button (2, Figure 4-13) once, heating off
Turn the knob (1) as far as it will go to cold position,
Turn the switch (5) to the required level.
For faster cooling, press in button (3) for Recirculation.
Switch the air conditioning on – press in button (4).