5. PARAMETERS
5.6 (D) Operation command and frequency command
5.6.6 JOG operation
The frequency and acceleration/deceleration time for JOG operation can be set. JOG operation is possible in both External
operation and PU.
JOG operation can be used for conveyor positioning, test run, etc.
Note that these parameters are categorized as a simple mode parameter when the LCD operation panel or the parameter unit
is used.
*1 The Pr.20 initial value is set to 60 Hz.
JOG operation in the External operation
Operation can be started and stopped by the start signals (STF and STR signals) when the Jog operation selection (JOG)
signal is ON. (For the operation method, refer to page 104.)
While the JOGF or JOGR signal is input, the Pr.15 Jog frequency setting is used for operation. The rotation is forward
while the JOGF signal is input, and the rotation is reverse while the JOGR signal is input. (Direct JOG function)
Use Pr.16 Jog acceleration/deceleration time to set the acceleration/deceleration time during JOG operation.
For each signal, refer to the following table and assign the function by Pr.178 to Pr.189 (Input terminal function
selection).
Pr. Name Initial value Setting range Description
15
D200
Jog frequency 5 Hz 0 to 590 Hz Sets the frequency during JOG operation.
16
F002
Jog acceleration/
deceleration time
0.5 s 0 to 3600 s Sets motor acceleration/deceleration time during JOG
operation. For the acceleration/deceleration time, set the time
until the frequency
*1
set to Pr.20 Acceleration/deceleration
reference frequency is reached.
The acceleration/deceleration times cannot be set separately.
Input signal Pr.178 to Pr.189 settings
JOG 5 (Pr.185 initial value)
JOGF 57
JOGR 58
Output frequency (Hz)
Pr.20
Pr.15
setting range
Pr.16
Forward
rotation
Reverse
rotation
Time
ON
ON
ON
JOG signal
Forward rotation STF
Reverse rotation STR
ON
ON
JOGF signal
JOGR signal
Time
Output frequency (Hz)
Pr.20
Pr.15
setting range
Pr.16
Forward
rotation
Reverse
rotation

Table of Contents

Other manuals for Mitsubishi Electric FR-F800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric FR-F800 and is the answer not in the manual?

Mitsubishi Electric FR-F800 Specifications

General IconGeneral
BrandMitsubishi Electric
ModelFR-F800
CategoryInverter
LanguageEnglish

Related product manuals