REVISIONS
*The manual number is given on the bottom left of the back cover.
Revision Date *Manual Number Revision
Oct. 2016 IB(NA)-0600688ENG-A First edition
Mar. 2019 IB(NA)-0600688ENG-B Added
Continuous operation during communication fault
Reset selection/disconnected PU detection/PU stop selection (Pr.75 = "1000 to 1003,
1014 to 1017, 1100 to 1103, 1114 to 1117")
Automatic restart after instantaneous power failure selection (Pr.162 = "1000 to 1003,
1010 to 1013")
Error reset operation selection at inverter fault (Pr.349 = "100, 101")
PLC function (Pr.414 ="11, 12", Pr.675)
Control method selection (Pr.800 = "109, 110")
Monitor with sign selection (Pr.1018 = "1")
Feb. 2022 IB(NA)-0600688ENG-C Added
Main circuit capacitor life measurement at power OFF (every time) (Pr.259 = "11")
Pr.506 Display estimated main circuit capacitor residual life
Current input check terminal selection (Pr.573 = "11 to 14, 21 to 24")
Low-speed forward rotation command (RLF) signal, Low-speed reverse rotation
command (RLR) signal
Reset selection after inverter faults are cleared (with the HMS network option
installed)
Cooling fan operation selection during the test operation (Pr.244 = "1000, 1001, 1101
to 1105")
Display/reset ABC relay contact life (Pr.507, Pr.508)
Reset selection after inverter faults are cleared, DriveControl writing restriction
selection (Pr.349 = "1000, 1001, 1100, 1101, 10000, 10001, 10100, 10101, 11000,
11001, 11100, 11101”)
Pr.890 Internal storage device status indication
Internal storage device fault (E.PE6)
Mar. 2023 IB(NA)-0600688ENG-D Added
Restricting reset method for an earth (ground) fault (Pr.249 ="2")
Output short-circuit detection (Pr.521)
Torque limit level 2 (Pr.815)
Deceleration time at emergency stop (Pr.1103, X92 signal)
Output short-circuit fault (E.SCF)
Edited
Pr.151, 153 setting range: 0 to 300 s
IB(NA)-0600688ENG-D

Table of Contents

Other manuals for Mitsubishi Electric FR-F800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric FR-F800 and is the answer not in the manual?

Mitsubishi Electric FR-F800 Specifications

General IconGeneral
BrandMitsubishi Electric
ModelFR-F800
CategoryInverter
LanguageEnglish

Related product manuals