[3] FUNCTIONS WHEN ENTERING THE SERVICE FACTORY MODE
User data
User data will be treated as follows :
• User data on picture-quality and audio-quality adjustments are not reflected, and factory-preset data are output
(user data will be retained in memory). When the unit enters Service Factory mode, the current audio-quality adjustment
data will be still be retained in memory.
• User-setting data will be applied to the various settings (items on the menus), signal formats, and the items that are
associated with path change (HDMI settings, etc.).
• Data on screen (i.e., screen position; meaning clock dividers, and not including data on screen size).
Are reset to the default values (data stored in memory will be retained).
Screen size will be retained.
The settings for the following functions are set to OFF when Service Factory mode is entered
(including when the “FAY” command is received) :
Note: Enter the factory after cancelling ACI because the ACI operation setting OFF and not done.
Fuctions whose setting are set to OFF
Function Remarks
2-Screen Operation Input function set on the main side is selected.
FREEZE
Auto size, Side Mask
ORBITER, Mask control Central value operation (ORBITER)
Sleep Timer Cancel the operation.
Room light sensor Turn off the detecting operation (Setting data will be retained.)
Blue LED dimmer Turn off the operation (Setting data will be retained.)
It is not performed during Factory mode.
Setting of Parental Control When this is turned off, the block of the screen is released.
Power Control Turn off the operation (However, the setting maintains it.)
Image Position Central value operation