Main flowchart (1)...Checking VOL OFFSET
[From Preparation]
Display RST MASK 09 (Pink). / [MKR S09]
To the Recovery flowchart (1-1)
To the Recovery flowchart (1-2)
Set VOL OFFSET to the tentative setting value minus 50. / [VOF ∗∗∗]
No
Ye s
Set VOL OFFSET to the tentative setting value plus 56. / [VOF ∗∗∗]
Display RST MASK 18 (Red 626). / [MKR S18]
No
Display RST MASK 19 (Green 626). / [MKR S19]
Display RST MASK 20 (Blue 626). / [MKR S20]
Return VOL OFFSET to the tentative setting value. / [VOF ∗∗∗]
Determine the tentative setting value for VOL OFFSET as
the final value.
Ye s
To the Recovery flowchart (1-3)
No
Ye s
To the Recovery flowchart (1-4)
From the Recovery flowchart (1-1) and (1-4)
Ye s
No
[To the Main flowchart (2)]
Is there erroneous discharge (abnormal lit cell)?
(Check on the PANEL 1-ADJ menu.)
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)