Page #98 background imageLoading...
Page #98 background image
98
PDP-5020FD
1
2 3 4
A
B
C
D
E
F
1
2 3 4
[2] QS2 (PANEL OPERATION DATA)
Data Arrangement
Data
Length
Output Example
ECO 3 byte QS2
1
Notify of the standby operation transition
1 byte 1
2 Adjustment flag of the main unit 1 byte 0
3 Adjustment-data backup flag 1 byte 0
4 "1st PD" data 1 byte 0
5 "2nd PD" data 1 byte 0
0
6 Color sensor data 1 byte
∗∗
∗∗∗∗
∗∗∗
7 Reserved 2 byte
8 Temperature data (TEMP 1) 3 byte 128
9 SD data 1 byte 0
10 SD subcategory data 1 byte 0
11 Operation status induced by SD 1 byte 0
12 Reserved 3 byte
00000259
13 HOUR METER 8 byte
0
0
0
0
14 MASK indication 1 byte 0
4A
15 Still picture detection 1 byte
16 SCAN protection detection 1 byte
17 Panel crack detection 1 byte
18
19
Address emergency detection 1 byte
Reserved 4 byte
CS
2 Byte 2 byte
1:
Power supply status
0
Shifting to Passive
Standby is not
possible.
P
During power ON
1
Shifting to Passive
Standby is possible.
2: Adjustment flag of
the main unit
0
Adjustment completed
1
Adjustment not
completed
3: Adjustment-data
backup flag
0 Adjustment completed
1
Adjustment not completed
4, 5: PD data
0 No PD data
2 POWER
3 SCAN
4 SCN-5V
6 Y-DCDC
7 Y-SUS
8 ADRS
A X-DCDC
10-1: SD subcategory (SQ_LSI)
0 No SD-Sub data
1 Communication error
2 Drive stop
3 BUSY
4 Version mismatching (H/S)
B X-SUS
C DIG-DCDC
F UNKNOWN
9: SD data
0 No SD
1 SQ_LSI
2 MDU-DEVICE
3 RST2
4 Panel temperature
11: Operation status
induced by SD
0 Normal
1 Relay-off completed
2
During warning
indication
14: MASK indication
0 MASK-OFF
1 MASK-ON
15 to 18: Detection of Each Protection function
0 Normal operation
1 At detection of protection operation
Command
Format
Effective Operation
Modes
Function Remarks
[QS2] Every Time
Output of status
Return data: 3 (ECO) + 34 (DATA) + 2 (CS) = 39 Byte
The command QS2 is for acquiring data on the panel's operational information.
10-2: SD subcategory (MDU-DEVICE)
0 No SD-Sub data
1 EEPROM
2 BACKUP
3DAC
6: Color sensor data
- Function OFF (including standby)
0 Normal
1 Hardware connection is not completed
2 Data mismatching
10-3: SD subcategory
(Panel temperature)
0 No SD-Sub data
1 Panel high temperature
2 Panel low temperature
5 Version mismatching (H/M)
6 Version mismatching (H/I)

Table of Contents

Other manuals for Pioneer PDP-5020FD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pioneer PDP-5020FD and is the answer not in the manual?

Pioneer PDP-5020FD Specifications

General IconGeneral
BrandPioneer
ModelPDP-5020FD
CategoryFlat Panel TV
LanguageEnglish

Related product manuals