Error Cause
13 Backup could not be completed (e.g. memory card removed during the backup)
14 Restoration not possible: Memory card is not inserted
15 Restoration not possible: Checksum of the NVRAM data backup file is faulty
16 Restoration not possible: No backup available
Note
The memory card must always remain inserted for the SIMOTION D410-2. For information
which
SINAMICS Control Units permit the removal of the memory card, refer to the SINAMICS
manuals.
Parameter p7775 is only reset automatically to 0 after the successful completion of a job.
Know-how and write protection
Parameter
p7775 is not part of the know-how protection. This allows the parameter to be read
and written independent of the know-how protection.
Parameter p7775 is part of the write protection. This means the parameter can only be written
by the controller that configured a PZD cyclic communication with the SINAMICS when write
protection is activated (p7761 = 1).
All other write jobs are acknowledged negatively, e.g.
SIMOTION SCOUT / STARTER
For SINAMICS BOP, IOP, AOP Control Units
Other masters that only communicate acyclically with the SINAMICS
7.4.6 SINAMICS diagnostic buffer
Requirements
The SINAMICS Integrated diagnostic buffer can be displayed in SIMOTION SCOUT.
Procedure
Select the SINAMICS Integrated in the project tree, and then "Target system" > "Device
diagnostics" in the menu.
In addition, the SINAMICS diagnostic buffer entries are also displayed in the
SIMOTION D410‑2 device diagnostics. All SIMOTION D410‑2 diagnostic buffer entries are
displayed first, and then all diagnostic buffer entries of the the SINAMICS Integrated. The start
of the SINAMICS Integrated diagnostic buffer entries is identified by the following entry:
>>>>>> Start of SINAMICS Integrated diagnostic buffer, station address = x <<<<<<
Commissioning (software)
7.4 Additional information on configuring the SINAMICS Integrated
SIMOTION D410-2
180 Commissioning and Hardware Installation Manual, 01/2015

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D410-2 DP and is the answer not in the manual?

Siemens SIMOTION D410-2 DP Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D410-2 DP
CategoryController
LanguageEnglish

Related product manuals