371 TOOL_REF_PROBE_AXIS2 - -
- Absolute position probe Y DOUBLE Immediately
-
- - 0 -999999.999 999999.999 2/2 M
Description: Absolute position probe Y
372 TOOL_REF_PROBE_AXIS3 - -
- Absolute position probe Z DOUBLE Immediately
-
- - 9 -999999.999 999999.999 2/2 M
Description: Absolute position probe Z
374 TOOL_WEAR_LIMIT_VALUE - -
- Limit value wear control on input DOUBLE Immediately
-
- - 9.999 0 9.999 2/2 M
Description: Limit value wear control on input
376 USER_CLASS_WRITE_CUS_DIR - -
- Write user cycles protection level BYTE Immediately
-
- 0 7 0 7 3/3 U
Description: Protection level User cycles for writing
377 USER_CLASS_WRITE_TO_MON_DAT - -
- Tool monitoring protection level BYTE Immediately
-
- 0 7 0 7 3/2 M
Description: Tool monitoring protection level
378 USER_CLASS_LADDER_VIEW - -
- Select User Ladder View protection level BYTE Immediately
-
- 0 2 0 7 2/2 M
Description: Select User Ladder View protection level
379 SPINDLE_DISP_MODE - -
- Spindle display mode BYTE Immediately
-
- 0 0 0 2 3/3 U
Description: 0: Standard Mode; spindle speed display
1: Constant cutting speed display when G96 is set
2: Mixed display
383 V24_PPI_ADDR_DRV1 - -
- Station address Drives BYTE PowerOn
-
- 0 5 0 126 3/3 U
Machine data
3.1 Display machine data
Parameter Manual
List Manual, 01/2017 31