Subsequent odd address: New identifier
The following three types of NC codes can reconfigured:
1. G codes e.g.: G02, G64, ASPLINE...
2. NC addresses e.g.: RND, CHF, ...
3. Pre-defined subprograms e.g.: CONTPRON, ...
10713 M_NO_FCT_STOPRE EXP, N12, N07 H2
- M function with preprocessing stop DWORD PowerOn
-
- 15 -1, -1, -1, -1, -1, -1, -1,
-1...
- - 2/2 M
Description: The M functions defined by MD10713 $MN_M_NO_FCT_STOPRE perform an implicit
preprocessing stop.
That is, the interpretation of the next part program line will be stopped until the
block with the M function defined in that way has been processed completely
(PLC acknowledgment, motion, etc.).
10714 M_NO_FCT_EOP EXP, N07 K1, H2
- M function for spindle active after reset DWORD PowerOn
-
808d-me42 - 32 - - 1/1 M
808d-me62 - 32 - - 1/1 M
808d-te42 - 32 - - 1/1 M
808d-te62 - 32 - - 1/1 M
808d-mte40 - -1 - - 2/2 M
808d-mte60 - -1 - - 2/2 M
Description: For spindles where a '2' is configured in MD35040 $MA_SPIND_ACTIVE_AFTER_RESET, no
spindle reset is
enabled with this M function when the part program is terminated. The
spindle therefore remains active after the end of the part program.
Proposal: M32
Restrictions: see MD10715 $MN_M_NO_FCT_CYCLE
Related to:
MD35040 $MA_SPIND_ACTIVE_AFTER_RESET
MD10714 $MN_M_NO_FCT_EOP,
MD10715 $MN_M_NO_FCT_CYCLE,
MD20094 $MC_SPIND_RIGID_TAPPING_M_NR,
MD22254 $MC_AUXFU_ASSOC_M0_VALUE
MD10814 $MN_EXTERN_M_NO_MAC_CYCLE,
MD20095 $MC_EXTERN_RIGID_TAPPING_M_NR
10715 M_NO_FCT_CYCLE EXP, N12, N07 H2, K1
- M function to be replaced by a subroutine DWORD PowerOn
-
- 30 -1, -1, -1, -1, -1, -1, -1,
-1...
- - 2/2 M
Description: M number with which a subprogram is called.
Machine data
3.2 General machine data
Parameter Manual
46 List Manual, 01/2017