6.6.3 Active alarm response
DB1600 Active alarm response [r]
PLC -> HMI interface
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
2000 Acknowledge
POWER ON
Acknowledge
with
DB1600DBX3
000.0
PLC STOP EMERGENCY
STOP
Feedrate disa‐
ble all axes
Read-in
disable
NC start
disable
2001
2002
2003
6.6.4 Alarm acknowledgement
DB1600 Alarm acknowledgement [r/w]
PLC -> HMI interface
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
3000 Ack
3001
3002
3003
6.7 Signals from/to HMI
6.7.1 Program control signals from the HMI (retentive area)
DB1700 Signals, HMI [r/w]
HMI -> PLC interface
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0 Dry run
feedrate
selected
M01 selec‐
ted
DRF selec‐
ted
1 Program
test selected
Feedrate
override se‐
lected for
rapid tra‐
verse
2 Skip block 7
selected
Skip block
6 selected
Skip block
5 selected
Skip block
4 selected
Skip block
3 selected
Skip block
2 selected
Skip block
1 selected
Skip block
0 selected
PLC user interface
6.7 Signals from/to HMI
Parameter Manual
List Manual, 01/2017 479