Description: Station address Drives
386 USER_CLASS_WRITE_CMA_DIR - -
- Defines the access level for the CMA directory in the NCK BYTE Immediately
-
- - 7 1 7 2/2 M
Description: Defines the access level for the CMA directory in the NCK
391 DISPLAY_MODE_INDEXING_AXIS - -
- Defines the display format of an indexing axis. DWORD Immediately
-
- - 0 0 1 7/2 M
Description: Defines the display format of an indexing axis.
0 = indexing position
1 = type-spec. actual value
392 USER_CLASS_WRITE_LOC_NO - -
- Access authorization for writing the location number into the tool
list
BYTE Immediately
-
- - 7 0 7 3/2 M
Description: Defines the access authorization for writing the location number in the tool list
395 COL_OVERSIZE_TYPE_CHECKBOX - -
- Check box in tool list BOOLEAN Immediately
-
- - 1 0 1 3/3 U
Description: Check box in tool list
9000 SCREEN_SAVER_WAIT_TIME - -
s Screen saver timeout. DWORD PowerOn
-
- - 3600 0 36000 1/1 M
Description: Screen saver timeout.
9001 TIME_BETWEEN_SLIDES - -
s Interval between pictures DWORD Immediately
-
- - 10 1 60 1/1 M
Description: Interval between pictures
3.2 General machine data
10000 AXCONF_MACHAX_NAME_TAB N01, N11 K2, F1, G2, F2, K5, M1
- Machine axis name STRING PowerOn
-
808d-me42 4 MX1, MY1, MZ1, MSP1 - - 2/2 M
Machine data
3.2 General machine data
Parameter Manual
32 List Manual, 01/2017