SWT 3000 Equipment Manual SNMP and Remote Access
© SIEMENS AG 2008 Edition p3_3_2x 08/09 Page - 23
RM in-band channel
In the case that no intranet or modems are available, the user can still monitor remote terminals
using the in-band RM channel. With the optional service “Remote Monitoring” (RM), data can be
transmitted between the devices of one or more SWT 3000 routes. The RM function enables the
user to have access via a serial interface with the service program to the following function:
y query of the device data (configuration, parameter, status) of the remote device
y temporary adjustments (e.g. test loops)
y producing a reset
Via an additional interface (service interface backplane SSB) up to 5 transmission routes can be
coupled.
Station 2 Station 3....Station 1
S
S
B
S
S
B
Adr.1 Adr.2
Adr.3
Adr.4
S
S
B
SWT 3000 SWT 3000 SWT 3000 SWT 3000
SSF Front interface on the PU3
SSB Back interface
Figure 17: Example of a route coupling with the RM function
Changing of the configuration and parameter (except date / time of the SWT 3000) in the remote
device is possible if the configuration via inband RM channel is activated (see figure below).
Figure 18: Configuration via RM inband channel
coupling of two
SWT 3000 routes