6-1-44 ENGINE GENERAL INFORMATION AND DIAGNOSIS (SFI FOR G13)
MAP Sensor Individual Check
1) Disconnect coupler from MAP sensor (1).
2) Remove MAP sensor (1).
3) Arrange 3 new 1.5 V batteries (2) in series (check that total volt-
age is 4.5 – 5.0 V) and connect its positive terminal to “Vin” termi-
nal of sensor and negative terminal to “Ground” terminal. Then
check voltage between “Vout” and “Ground”.
Also, check if voltage reduces when vacuum is applied up to 400
mmHg by using vacuum pump (3).
Output voltage (Vin voltage 4.5 – 5.5 V, ambient temp. 20 –
30_C, 68 – 86_F)
ALTITUDE
BAROMETRIC OUTPUT
(Reference) PRESSURE VOLTAGE
(ft) (m) (mmHg) (kPa) (V)
0
If check result is not satisfactory, replace MAP sensor (1).
4) Install MAP sensor (1) securely.
5) Connect MAP sensor (1) coupler securely.