8G-18 IMMOBILIZER CONTROL SYSTEM
09931-76030
16/ 14 pin DLC cable
09931-76011
Suzuki scan tool (Tech 1A kit)
1. Storage case
2. Operator’s manual
3. Tech 1A
4. DLC cable
(14/ 26 pin, 09931-76040)
5. Test lead / probe
6. Power source cable
7. DLC cable adapter
8. Self-test adapter
Immobilizer cartridge of
version 1.1 or more
NOTE:
Use this cable only with im-
mobilizer cartridge of ver-
sion 1.1 or more.
Use of this cable with 96
immobilizer cartridge will
disable 96 immobilizer car-
tridge from operating prop-
erly.
Mass storage cartridge of
version 1.5 or more
PROCEDURE AFTER ECM
REPLACEMENT
When ECM was replaced, including when replaced because re-
checking by using a known-good ECM was necessary during
trouble diagnosis, register ECM/Immobilizer Control Module code
in ECM by performing following procedure.
1) Perform Steps 1) and 2) described in “How to register ignition
key” section. And then turn ignition switch ON.
2) Using Suzuki scan tool, register ECM/Immobilizer Control Module
code in ECM by executing “RECORD ECU (RECORD ECM/Im-
mobilizer Control Module)” command in SELECT MODE menu.
NOTE:
For operation procedure of Suzuki scan tool, refer to Suzuki
scan tool operator’s manual.
3) [Vehicle equipped with monitor coupler]
Make sure that malfunction indicator lamp lights when ignition
switch is turned OFF once and then ON.
[Vehicle not equipped with monitor coupler]
Make sure that immobilizer indicator lamp lights when ignition
switch is turned OFF once and then ON.
SPECIAL TOOLS