6F-6 IGNITION SYSTEM
6) If resistance exceeds specification, inspect distributor terminal
and replace high-tension cord(s) and/or distributor cap as re-
quired.
CAUTION:
D Never attempt to use metal conductor high-tension cords
as replacing parts.
D Insert each cap portion fully when installing high-tension
cords.
SPARK PLUGS
1) Pull out high-tension cords by gripping their caps and then re-
move spark plugs.
2) Inspect them for:
D Electrode wear
D Carbon deposits
D Insulator damage
3) If any abnormality is found, adjust air gap, clean with spark plug
cleaner or replace them with specified new plugs.
Spark plug air gap “a’’ : 1.0 – 1.1 mm (0.039 – 0.043 in.)
Spark plug type : NGK BPR6ES-11
: DENSO W20EPR-U11
4) Install spark plugs and torque them to specification.
Tightening Torque for spark plug
25 N
.
m (2.5 kg-m, 18.0 lb-ft)
5) Install high-tension cords securely by gripping their caps.
NOISE SUPPRESSOR
REMOVAL
1) Unwrap tape from noise suppressor.
2) Disconnect coupler of noise suppressor.
3) Remove noise suppressor.
INSTALLATION
Reverse removal procedure for installation.
INSPECTION
Using an ohmmeter (1) to check continuity as the following.
“a” – “b”: No continuity
“a” – “c”: No continuity
“c” – “d”: Continuity (Approx. 2.2 kΩ)
If check result is not satisfactory, replace noise suppressor (2).