ENGINE AND EMISSION CONTROL SYSTEM (TBI FOR G10) 6E1-31
1. RFC relay
2. Relay box
RADIATOR FAN CONTROL RELAY (RFC RELAY)
INSPECTION
1) Disconnect negative cable at battery.
2) Remove RFC relay from relay box.
3) Structure of RFC relay is the same as that of main relay.
Check its resistance and operation using the same procedure as
that for main relay. If found defective, replace.
RADIATOR FAN
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect radiator fan motor connector.
3) Connect battery to the motor and check for operation.
If fan fails to operate, replace.