: Tightening Torque
: Do not reuse
1. Exhaust manifold
2. Gasket
3. Cover
4. Heated oxygen sensor
7. Gasket
8. Exhaust No.1 pipe.
2
1
ENGINE MECHANICAL (G13B, 1-CAM 16-VALVES ENGINE) 6A1-17
EXHAUST MANIFOLD
WARNING:
To avoid danger of being burned, do not service exhaust
system while it is still hot.
Service should be performed after system cools down.
REMOVAL
1) Disconnect negative cable at battery.
2) Disconnect heated oxygen sensor coupler.
Release its wire from clamps.
3) Disconnect exhaust No.1 pipe (1) from WU-TWC.
4) Remove WU-TWC stiffener (2) (if equipped).
5) Remove exhaust manifold (1) and its gasket from cylinder head.