8-10 SHB 28Z3 EN – Edition 2.0 * 28z3s810.fm
PowerTilt PTS06
8.7 Removing the standard journal coupling
☞ Remove all 4 connecting plugs c (on left and right) from the housing and drain the oil
into a container.
☞ When the oil has been drained, fit the connecting plug back on again.
Notice!
Check the oil for signs of contamination (water) and metal particles.
☞ Slacken the 4 fastening screws of shaft a and remove them with plate washer b from
standard journal coupling 6 or from the drive-side 6.1 and end-cap side 6.2 base block.
Caution!
In order to avoid personal injury and damage to the equipment:
☞ Before removing the screws from securing ring d, secure the standard
journal coupling with lifting gear or similar equipment.
☞ Remove screws d of securing ring 5.
☞ Tighten both set screws e on securing ring 5. Turn the screws alternately to remove the
securing ring from end cap 4 and base block 6.2 on the end-cap side.
Fig. 4: Removing the connecting plug
1
c
Torque specifications for the connecting plug
Plug size Torque values Nm (lbs/ft)
BSPP G1/4 31 +/- 1 (22.9 +/- 0.7)
Fig. 5: Removing the fastening screws from the shaft
a
b
Fig. 6: Securing the coupling
Fig. 7: Securing the coupling
5
d
Fig. 8: Tightening the set screws
e