Installation and Setup
50
Hardware Reference Manual – Enova DGX 100 Series Digital Media Switchers
Indicator Lights at Startup
When the enclosure powers up, the indicator LEDs respond as follows:
* The system was in the process of upgrading the last time it was powered down; wait for upgrade to finish (see page 210).
IMPORTANT: If the indicator LEDs do not respond with a normal display as stated in the table above, check power connections,
before contacting technical support (see page 61).
Redundant Power Supply (RPS)
IMPORTANT: Enova DGX 6400 only – If two or more power supplies are not receiving power, the CPU and the control panel will
continue to operate. However, input and output boards will become inoperable and the system will not send or receive signals until at
least three power supplies resume functional status.
Every Enova DGX 800/1600/3200 enclosure ships with two mutually-redundant (hot-swappable) power supplies; every Enova DGX
6400 enclosure ships with four.
Enova DGX 800/1600/3200 – Power indicator on the front of the enclosure illuminates constant red if a problem occurs
with one or more power supplies.
Enova DGX 6400 – Power indicator on the front of the enclosure illuminates constant red if a problem occurs with one
power supply and flashing red if two or three power supplies experience problems.
Check the AC and DC LED indicators on the left of each power receptacle to determine if a power supply is not working. For
additional LED information, see above.
IMPORTANT: A failed power supply should be replaced as soon as possible to maintain the system’s power redundancy. For
replacement information, contact technical support (see page 61).
Power Supply Troubleshooting
If a power supply’s AC and DC power indicator LEDs are not illuminated: Check to be sure the power cord is completely plugged
into the enclosure and the power source.
If a power supply’s DC LED illuminates amber or red, contact technical support (see page 61).
CAUTION: Do not remove a failed power supply until the replacement is ready to install, unless directed to do so by technical
support.
Enova DGX LED Indicators
LED Indicates Normal Display Cautionary
Front Power System power status Constant green Constant red: one power supply is
not working
Enova DGX 6400 only -
Constant red: one power supply is
not working
Flashing red: two or three power
supplies are not working
Flashing green: System in upgrade
process*
Rear –
Power
Supplies
AC Power AC power presence Constant green Not illuminated: AC failure
DC Power
(Tri-color LED)
DC power present
Power supply
temperature
Fault Status
Constant green Not illuminated: DC failure
Amber: power supply is over
temperature
Red: power supply is in a fault
state
Rear –
CPU
Status System status Solid amber during boot load (10 sec)
Solid green during app load
(1-4 minutes, depending on system
configuration)
Flashing green when ready
Blinking red/green: MCPU is in a fault
state. Power cycle may recover;
otherwise, contact technical support.
LAN 100/1000
and ICS LAN
L/A
SPD
Cables are connected
and terminated correctly
Receiving or transmitting
LAN data packets
Constant green
Blinks yellow