59.8 Test Call Configuration Examples
Below are a few examples of test call configurations.
Single Test Call Scenario: This example describes the configuration of a simple test
call scenario that includes a single test call between a simulated test endpoint on the
device and a remote endpoint.
Figure 59-8: Single Test Call Example
Test Call Rules table configuration:
Endpoint URI: "101"
Called URI: "201"
Route By: Dest Address
Destination Address: "10.30.40.01"
SIP Interface: SIPInterface_0
Call Party: Caller
Test Mode: Once
Alternatively, if you want to route the test call using the Tel-to-IP Routing table for the
Gateway application, configure the following:
Test Call Rules table configuration:
Endpoint URI: 101@10.0.0.1
Route By: Tel-to-IP
SIP Interface: SIPInterface_0
Called URI: 201@10.30.40.1
Call Party: Caller
Tel-to-IP Routing table configuration:
Destination Phone Prefix: 201 (i.e., the Called URI user-part)
Source Phone Prefix: 101 (i.e., the Endpoint URI user-part)
Destination IP Address: 10.30.40.1

Table of Contents

Other manuals for AudioCodes MSBG Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MSBG Series and is the answer not in the manual?

AudioCodes MSBG Series Specifications

General IconGeneral
BrandAudioCodes
ModelMSBG Series
CategoryGateway
LanguageEnglish

Related product manuals