D9412GV4/D7412GV4 v2.03 | Installation and System Reference Guide | 18.0 Installer Menu
.
Bosch Security Systems, Inc. | 7/16 | F01U265457-09 109
2. Go to the [1] Program > [1] Reporting > [1] Phone > [1] Phone Format menu option. The
keypad shows the phone number for the phone path.
3. Use /[PREV] or /[NEXT] to go to the path you wish to edit.
4. Press the Format softkey to view and change the phone format, and then press the Edit
softkey to edit the phone format.
5. Press the softkey for the desired format.
6. Press the Save softkey.
7. When the keypad shows Parameter Saved, escape from the menu.
18.1.2 [1] Reporting > [2] Network Menu Parameters
Enhanced communications is the ability to communicate by some means other than a standard digital
dialer. The control panel can include four separate enhanced communication paths to which the
control panel can route events. In this menu, you can enable enhanced communication and edit the
network address, network address, poll rate, and port number.
Path 1 Nework Address
_
________________________
_
Poll Rate ___________ Port Number ________
Path 2 Nework Address
_
________________________
_
Poll Rate ___________ Port Number ________
Path 3 Nework Address
_
________________________
_
Poll Rate ___________ Port Number ________
Path 4 Nework Address
_
________________________
_
Poll Rate ___________ Port Number ________
Enhanced Comm
B91x/B92x keypads Configuration of Enhanced Comm
1. Enter the installer passcode, and then go to the [1] Installer menu.
2. Go to the [1] Program > [1] Reporting > [2] Network > [1] Enhanced Comm menu option.
The keypad displays the Enhanced Comm option as well as the current default value.
3. Press [ENTER] to edit the enhanced comm. menu.
4. Use the [PREV] and [NEXT] buttons to toggle between the Yes and No options.
5. Press [ENTER] while reviewing the desired option to save the new communication selection.
6. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads Configuration of Enhanced Comm
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to the [1] Program > [1] Reporting > [2] Network > [1] Enhanced Comm menu option.
The keypad displays the enhanced comm option as well as the current default value.
3. Press the Enhanced Comm softkey to view and change the enhanced comm option, and then
press the Edit softkey to edit the enhanced communication option.
4. Press the softkey for the desired format.
5. Press the Save softkey.
6. When the keypad shows Parameter Saved, escape from the menu.

Table of Contents

Other manuals for Bosch D9412GV4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch D9412GV4 and is the answer not in the manual?

Bosch D9412GV4 Specifications

General IconGeneral
Power Supply12 VDC
TypeControl Panel
ModelD9412GV4
ManufacturerBosch
Operating Temperature0°C to +49°C (+32°F to +120°F)
Compatible withConettix IP, GSM, GPRS, and POTS communicators

Related product manuals