D9412GV4/D7412GV4 v2.03 | Installation and System Reference Guide | 18.0 Installer Menu
.
Bosch Security Systems, Inc. | 7/16 | F01U265457-09 135
RFID
B91x/B92x keypads Configuration of RFID
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to the [1] Program > [7] Points menu option. The keypad display toggles between
showing the point index and point source for the selected point.
3. Press [PREV] and [NEXT] to the desired point, or enter the point number.
4. Press [ENTER] to edit the point and then [NEXT] to go to the RFID option if the source is
Wireless.
5. Press [ENTER] to edit the RFID for the selected point.
6. The [ESC] key acts as a backspace key. Press [ESC] to delete the numbers, if applicable, and
then enter the new RFID listed on the wireless device.
7. Press [ENTER] while viewing the desired RFID number to save the programming.
8. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads Configuration of RFID
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to the [1] Program > [7] Points menu option. The keypad display scrolls between showing
the point index and point source for the selected point.
3. Press [PREV]/ and [NEXT]/ to go to the desired point, or enter the point number.
4. Press the [Source] softkey to view and edit the source. If the source is Wireless, the [RFID]
softkey appears.
5. Press [RFID] to edit the RFID.
6. On the B93x, the [ESC] key acts as a backspace key. The B94x has a [Backspace] key. Delete
the numbers, if applicable, and then enter the new RFID listed on the wireless device.
7. Press the Save softkey.
8. When the keypad shows Parameter Saved, escape from the menu.
18.1.16 [8] Disable Programming Menu Parameters
Use of the Keypad Installer menu is enabled by default. When enabled, the Service User (Authority
Level 15) has authority to access the menus. If you disable Keypad Programming, the Service User
cannot access the menus. In this menu, you can disable Keypad Programming.
You can continue using the current programming session. Disabling Keypad
Programming applies once you exit the current session.
Disable Programming
B91x/B92x keypads Configuration of Keypad Programming
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to the [1] Program > [8] Disable Programming menu option. The keypad display shows
that programming is enabled.
3. Press [ENTER] to disable keypad programming, and then press [NEXT] to go to the No option.
4. Press [ENTER] to save the programming.
5. When the keypad shows Parameter Saved, escape from the menu.

Table of Contents

Other manuals for Bosch D9412GV4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch D9412GV4 and is the answer not in the manual?

Bosch D9412GV4 Specifications

General IconGeneral
Power Supply12 VDC
TypeControl Panel
ModelD9412GV4
ManufacturerBosch
Operating Temperature0°C to +49°C (+32°F to +120°F)
Compatible withConettix IP, GSM, GPRS, and POTS communicators

Related product manuals