D9412GV4/D7412GV4 v2.03 | Installation and System Reference Guide | 10.0 Off-Board Outputs
.
Bosch Security Systems, Inc. | 7/16 | F01U265457-09 60
10.0 Off-Board Outputs
10.1 D8129 OctoRelay
Use the D8129 OctoRelay to add relay outputs to
the system in groups of eight. On the D9412GV4,
up to 128 OctoRelay outputs (output numbers 1
to 128) can be added to the system using 16
OctoRelays. D7412GV4 allows up to 64 output
outputs. Review Section 6.0 Power Outputs on
page 34 to ensure that enough power is provided
for the OctoRelays and other powered devices
that are connected to the system.
OctoRelays for output numbers 1 to 64 connect
to Zonex 1, Terminal 28. OctoRelays for output
numbers 65 to 128 connect to Zonex 2
(D9412GV4 only), Terminal 26. Refer to Figure 22
or Error! Reference source not found. on
page Error! Bookmark not defined..
Alarm output, auxiliary relay, sensor reset, arming
status, point status, alarm memory, or remote
functions can be assigned to the OctoRelay
outputs individually. Refer to Relay Parameters in
the Control Panels (D9412GV4/D7412GV4 v2.03)
Program Entry Guide (P/N: F01U265459) for
programming details.
D8129 Restricted for Fire Systems: D8129 relay
outputs are not supervised and cannot be used in
fire or combined fire and burglary installations for
primary indicating devices.