D9412GV4/D7412GV4 v2.03 | Installation and System Reference Guide | 18.0 Installer Menu
.
Bosch Security Systems, Inc. | 7/16 | F01U265457-09 125
7. Enter in the desired account number. The Cancel softkey allows you to cancel the changes.
8. Press the Save softkey.
9. When the keypad shows Parameter Saved, escape from the menu.
18.1.13 [5] Keypad > [1] Scope Menu Parameters
The scope of a keypad defines which areas the keypad affects when armed, which areas you can view
with this keypad, and the areas to which this keypad can move. In this menu, you can choose the
keypad’s scope.
Scope (Circle one)
Keypad 1 No Device / Area Wide / Acct Wide / Panel Wide
Keypad 2 No Device / Area Wide / Acct Wide / Panel Wide
Keypad 3 No Device / Area Wide / Acct Wide / Panel Wide
Keypad 4 No Device / Area Wide / Acct Wide / Panel Wide
Keypad 5 No Device / Area Wide / Acct Wide / Panel Wide
Keypad 6 No Device / Area Wide / Acct Wide / Panel Wide
Keypad 7 No Device / Area Wide / Acct Wide / Panel Wide
Keypad 8 No Device / Area Wide / Acct Wide / Panel Wide
Scope
B91x/B92x keypads Configuration of Scope
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to the [1] Program > [5] Keypad menu option. The keypad shows scope for the selected
keypad.
3. Press [PREV] and [NEXT] to go to the desired keypad.
4. Press [ENTER] to edit the scope.
5. Press [PREV] or [NEXT] to go to the desired scope.
6. Press [ENTER] while viewing the desired scope to save the new format selection.
7. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads Configuration of Scope
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to the [1] Program > [5] Keypad menu option. The keypad shows scope for the selected
keypad.
3. Use /[PREV] or /[NEXT] to go to the desired keypad.
4. Press the Edit softkey to edit the scope.
5. Press the softkey for the desired format.
6. Press the Save softkey.
7. When the keypad shows Parameter Saved, escape from the menu.

Table of Contents

Other manuals for Bosch D9412GV4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch D9412GV4 and is the answer not in the manual?

Bosch D9412GV4 Specifications

General IconGeneral
Power Supply12 VDC
TypeControl Panel
ModelD9412GV4
ManufacturerBosch
Operating Temperature0°C to +49°C (+32°F to +120°F)
Compatible withConettix IP, GSM, GPRS, and POTS communicators