D9412GV4/D7412GV4 v2.03 | Installation and System Reference Guide | 18.0 Installer Menu
.
Bosch Security Systems, Inc. | 7/16 | F01U265457-09 114
6. Press [ENTER]. The keypad shows Set Route Device menu.
7. Press [PREV] or [NEXT] to scroll through the list of devices (for path 1) and go to the Path 1
option you wish to select for the current device (for example, Phone 1).
8. Press [ENTER] to select the device. The keypad shows Set Route Path. To keep path 1,
escape from the menu. To change to a different path (2, 3, or 4), continue to Step 8.
9. Delete existing characters, if necessary, and then enter the new phone number.
10. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads Configuration of Backup Path Device
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to the [1] Program > [1] Reporting > [3] Routing menu option. The keypad displays the
primary device for the selected route.
3. Press [PREV]/ or [NEXT]/ to scroll through the list of routes and go to the route you wish
to program.
4. Press the Backup softkey to edit the backup path device for the selected route.
5. Press [PREV]/ or [NEXT]/ to scroll through the list of devices (for path 1) and go to the
path 1 option you wish to select for the current device (for example, Phone 1).
6. To keep path 1, escape from the menu. To change to a different path (2, 3, or 4), press the
Edit Path softkey and continue to Step 8.
7. Delete existing characters, if necessary, and then enter the new phone number.
8. Press the Save softkey to save the change.
9. When the keypad shows Parameter Saved, escape from the menu.
18.1.4 [2] Network > [1] Bus Module (1) or [2] Bus Module (2) Module Parameters
You can use DHCP/AutoIP or UpnP for communication with a B420 module. In this menu, you can
enable and disable these protocols. In other B42x menus, you can set other B420 parameters.
Default Module settings Module settings
DHCP/AutoIP Enable Yes Yes/No Yes/No
UpnP Enable Yes Yes/No Yes/No
IPv4 Address 0.0.0.0 _________________________ _________________________
IPv4 Subnet Mask 255.255.255.255 _________________________ _________________________
Default Gateway 0.0.0.0 _________________________ _________________________
HTTP Port Number 80 _________________________ _________________________
IPv4 Server Address 0.0.0.0 _________________________ _________________________
IPv6 Server Address
(B426 only)
0.0.0.0 _________________________ _________________________
Module Hostname Blank _________________________ _________________________

Table of Contents

Other manuals for Bosch D9412GV4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch D9412GV4 and is the answer not in the manual?

Bosch D9412GV4 Specifications

General IconGeneral
Power Supply12 VDC
TypeControl Panel
ModelD9412GV4
ManufacturerBosch
Operating Temperature0°C to +49°C (+32°F to +120°F)
Compatible withConettix IP, GSM, GPRS, and POTS communicators

Related product manuals