EasyManuals Logo

Dell PowerVault MD3200i User Manual

Dell PowerVault MD3200i
282 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #102 background imageLoading...
Page #102 background image
102 Configuration: About Your Host
4
Click
Action
Start
.
I/O Data Path Protection
You can have multiple host-to-array connections for a host. Ensure that you
select all the connections to the array when configuring host access to the
storage array.
NOTE: See the Deployment Guide for more information on cabling configurations.
NOTE: For more information on configuring hosts see "Configuration: About Your
Host" on page 95.
If a component such as a RAID controller module or a cable fails, or an error
occurs on the data path to the preferred RAID controller module, the virtual
disk ownership is moved to the alternate non preferred RAID controller
module for processing. This failure or error is called failover.
Drivers for multi-path frameworks such as Microsoft Multi-Path IO (MPIO)
and Linux Device Mapper (DM) are installed on host systems that access the
storage array and provide I/O path failover.
For more information on Linux DM, see "Configuration: Device Mapper
Multipath for Linux" on page 189. For more information on MPIO, see
microsoft.com.
NOTE: You must have the multi-path driver installed on the hosts at all times, even
in a configuration where there is only one path to the storage system, such as a
single port cluster configuration.
During a failover, the virtual disk transfer is logged as a critical event, and an
alert notification is sent automatically if you have configured alert
destinations for the storage array.
book.book Page 102 Saturday, September 24, 2011 9:06 AM

Table of Contents

Other manuals for Dell PowerVault MD3200i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerVault MD3200i and is the answer not in the manual?

Dell PowerVault MD3200i Specifications

General IconGeneral
HDD speed15000 RPM
RAID levels0, 1, 5, 6, 10
Storage drive capacity600 GB
Storage drive interfaceSerial Attached SCSI (SAS)
Maximum supported storage capacity115.2 TB
Number of storage drives installed12
InterfaceRJ-45, SAS, PS/2
Connector(s)4x RJ-45, 1x 6Gb SAS, 1x PS/2
Power supply typeAC
Dimensions (WxDxH)446.3 x 561 x 86.8 mm
Power requirements90 - 264 V, 47 - 63 Hz
Networking featuresGigabit Ethernet
Compatible operating systemsWindows, Linux, VMware, Hyper-V
InternalNo
LED indicatorsHDD, Power, Power fail, Status
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)20 - 80 %
Power consumption (typical)25 W
Power supply unit (PSU) capacity600 W
Weight and Dimensions IconWeight and Dimensions
Weight29300 g