Configuration: Disk Groups and Virtual Disks 133
associated source virtual disk. Changing the RAID controller module
ownership of a virtual disk changes the preferred RAID controller module
ownership of the virtual disk.
During a virtual disk copy, the same RAID controller module must own both
the source virtual disk and the target virtual disk. Sometimes both virtual
disks do not have the same preferred RAID controller module when the
virtual disk copy starts. Therefore, the ownership of the target virtual disk is
automatically transferred to the preferred RAID controller module of the
source virtual disk. When the virtual disk copy is completed or is stopped,
ownership of the target virtual disk is restored to its preferred RAID controller
module. If ownership of the source virtual disk is changed during the virtual
disk copy, ownership of the target virtual disk is also changed. Under certain
operating system environments, it may be necessary to reconfigure the multi-
path driver before an I/O path can be used.
To change the RAID controller module ownership of a disk group:
1
In the AMW, select the
Logical
tab and select a disk group.
2
Select
Disk Group
Change
Ownership/Preferred Path
.
3
Select the appropriate RAID controller module slot and click
Yes
to
confirm the selection.
CAUTION: Possible loss of data access – Changing ownership at the disk group
level causes every virtual disk in that disk group to transfer to the other RAID
controller module and use the new I/O path. If you do not want to set every virtual
disk to the new path, change ownership at the virtual disk level instead.
The ownership of the disk group is changed. I/O to the disk group is now
directed through this I/O path. You are finished with this procedure.
NOTE: The disk group may not use the new I/O path until the multi-path driver
reconfigures and recognizes the new path. This action usually takes less than 5
minutes.
Changing the RAID Level of a Disk Group
Changing the RAID level of a disk group changes the RAID levels of every
virtual disk that comprises the disk group. Performance may be slightly
affected during the operation.
Guidelines to change the RAID level of a disk group:
You cannot cancel this operation after it begins.
book.book Page 133 Saturday, September 24, 2011 9:06 AM

Table of Contents

Other manuals for Dell PowerVault MD3200i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerVault MD3200i and is the answer not in the manual?

Dell PowerVault MD3200i Specifications

General IconGeneral
HDD speed15000 RPM
RAID levels0, 1, 5, 6, 10
Storage drive capacity600 GB
Storage drive interfaceSerial Attached SCSI (SAS)
Maximum supported storage capacity115.2 TB
Number of storage drives installed12
InterfaceRJ-45, SAS, PS/2
Connector(s)4x RJ-45, 1x 6Gb SAS, 1x PS/2
Power supply typeAC
Dimensions (WxDxH)446.3 x 561 x 86.8 mm
Power requirements90 - 264 V, 47 - 63 Hz
Networking featuresGigabit Ethernet
Compatible operating systemsWindows, Linux, VMware, Hyper-V
InternalNo
LED indicatorsHDD, Power, Power fail, Status
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)20 - 80 %
Power consumption (typical)25 W
Power supply unit (PSU) capacity600 W
Weight and Dimensions IconWeight and Dimensions
Weight29300 g

Related product manuals