Configuration: Disk Groups and Virtual Disks 143
For more information, see the PowerVault Modular Disk Storage Manager
online help topics.
Disk Group Migration
Disk group migration allows to you export a disk group so that you can import
the disk group to a different storage array. You can also export a disk group so
that you can store the data offline.
NOTE: During the export process (before the disk group is imported) you lose
access to the data on the exported disk group.
NOTE: You must export a disk group before you move the disk group or import the
disk group.
Export Disk Group
The export disk group operation prepares the physical disks in the disk group
for removal. You can remove the physical disks for offline storage, or you can
import the disk group to a different storage array. After you complete the
export disk group operation, all of the physical disks are offline. Any
associated virtual disks or free capacity nodes are no longer shown in MDSM.
Non-Exportable Components
You must remove or clear any non-exportable settings before you can
complete the export disk group procedure. Remove or clear the following
settings:
Persistent reservations
Host-to-virtual disk mappings
Virtual disk copy pairs
Snapshot virtual disks and snapshot repository virtual disks
Remote mirror pairs
Mirror repositories
Exporting a Disk Group
On the source storage array:
1
Save the storage array configuration.
book.book Page 143 Saturday, September 24, 2011 9:06 AM

Table of Contents

Other manuals for Dell PowerVault MD3200i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerVault MD3200i and is the answer not in the manual?

Dell PowerVault MD3200i Specifications

General IconGeneral
HDD speed15000 RPM
RAID levels0, 1, 5, 6, 10
Storage drive capacity600 GB
Storage drive interfaceSerial Attached SCSI (SAS)
Maximum supported storage capacity115.2 TB
Number of storage drives installed12
InterfaceRJ-45, SAS, PS/2
Connector(s)4x RJ-45, 1x 6Gb SAS, 1x PS/2
Power supply typeAC
Dimensions (WxDxH)446.3 x 561 x 86.8 mm
Power requirements90 - 264 V, 47 - 63 Hz
Networking featuresGigabit Ethernet
Compatible operating systemsWindows, Linux, VMware, Hyper-V
InternalNo
LED indicatorsHDD, Power, Power fail, Status
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)20 - 80 %
Power consumption (typical)25 W
Power supply unit (PSU) capacity600 W
Weight and Dimensions IconWeight and Dimensions
Weight29300 g

Related product manuals