Configuration: Disk Groups and Virtual Disks 137
You cannot move a host with a restricted host type into a storage partition
that already has LUNs mapped that are greater than what is allowed by the
restricted host type. For example, if you have a restricted host type that
allows only LUNs up to 31, you cannot move that restricted host type into
a storage partition that has LUNs greater than 31 already mapped.
The Default Group on the Mappings tab has a default host type. You can
change this type by selecting Storage Array Change Default Host Type.
If you set the default host type to a host type that is restricted, the maximum
number of LUNs that are allowed in the Default Group for any host are
restricted to the limit imposed by the restricted host type. If a particular host
with a non-restricted host type becomes part of a specific storage partition,
you can change the mapping to a higher LUN.
Changing the RAID Controller Module Ownership of a Virtual Disk or a
Disk Group
You can change the RAID controller module ownership of a virtual disk or a
disk group.
You can change the RAID controller module ownership of a standard virtual
disk or a snapshot repository virtual disk. You cannot directly change the
RAID controller module ownership of a snapshot virtual disk because the
snapshot virtual disk inherits the RAID controller module owner of its
associated source virtual disk. Changing the RAID controller module
ownership of a virtual disk changes the preferred RAID controller module
ownership of the virtual disk.
During a virtual disk copy, the same RAID controller module must own both
the source virtual disk and the target virtual disk. Sometimes both virtual
disks do not have the same preferred RAID controller module when the
virtual disk copy starts. Therefore, the ownership of the target virtual disk is
automatically transferred to the preferred RAID controller module of the
source virtual disk. When the virtual disk copy is completed or is stopped,
ownership of the target virtual disk is restored to its preferred RAID controller
module. If ownership of the source virtual disk is changed during the virtual
disk copy, ownership of the target virtual disk is also changed. Under certain
operating system environments, it may be necessary to reconfigure the multi-
path driver before an I/O path can be used.
1
To change:
book.book Page 137 Saturday, September 24, 2011 9:06 AM

Table of Contents

Other manuals for Dell PowerVault MD3200i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerVault MD3200i and is the answer not in the manual?

Dell PowerVault MD3200i Specifications

General IconGeneral
HDD speed15000 RPM
RAID levels0, 1, 5, 6, 10
Storage drive capacity600 GB
Storage drive interfaceSerial Attached SCSI (SAS)
Maximum supported storage capacity115.2 TB
Number of storage drives installed12
InterfaceRJ-45, SAS, PS/2
Connector(s)4x RJ-45, 1x 6Gb SAS, 1x PS/2
Power supply typeAC
Dimensions (WxDxH)446.3 x 561 x 86.8 mm
Power requirements90 - 264 V, 47 - 63 Hz
Networking featuresGigabit Ethernet
Compatible operating systemsWindows, Linux, VMware, Hyper-V
InternalNo
LED indicatorsHDD, Power, Power fail, Status
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)20 - 80 %
Power consumption (typical)25 W
Power supply unit (PSU) capacity600 W
Weight and Dimensions IconWeight and Dimensions
Weight29300 g

Related product manuals