EasyManuals Logo

Dell PowerVault MD3200i User Manual

Dell PowerVault MD3200i
282 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #110 background imageLoading...
Page #110 background image
110 Configuration: Disk Groups and Virtual Disks
Use recommended settings
.
Customize settings
.
6
Click
Next
.
7
In the
Customize Advanced Virtual Disk Parameters
window, select the
appropriate Virtual Disk I/O characteristics type. You can select:
File system (typical)
Database
•Multimedia
•Custom
NOTE: If you select Custom, you must select an appropriate segment size.
8
Select the appropriate
Preferred RAID controller module ownership
and
click
Next
.
The
Specify Virtual Disk-to-LUN Mapping
window is displayed.
9
In the
Specify Virtual Disk-to-LUN Mapping
window, you can select:
•Default Mapping
The appropriate
Host type
Map later Using Mappings View
.
10
Click
Finish
.
The virtual disks are created.
Changing the Virtual Disk Modification Priority
You can specify the modification priority setting for a single virtual disk or
multiple virtual disks on a storage array.
Guidelines to change the modification priority of a virtual disk:
If more than one virtual disk is selected, the modification priority defaults
to the lowest priority. The current priority is shown only if a single virtual
disk is selected.
Changing the modification priority by using this option modifies the
priority for the selected virtual disks.
To change the virtual disk modification priority:
1
In the AMW, select the
Logical
tab.
book.book Page 110 Saturday, September 24, 2011 9:06 AM

Table of Contents

Other manuals for Dell PowerVault MD3200i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerVault MD3200i and is the answer not in the manual?

Dell PowerVault MD3200i Specifications

General IconGeneral
HDD speed15000 RPM
RAID levels0, 1, 5, 6, 10
Storage drive capacity600 GB
Storage drive interfaceSerial Attached SCSI (SAS)
Maximum supported storage capacity115.2 TB
Number of storage drives installed12
InterfaceRJ-45, SAS, PS/2
Connector(s)4x RJ-45, 1x 6Gb SAS, 1x PS/2
Power supply typeAC
Dimensions (WxDxH)446.3 x 561 x 86.8 mm
Power requirements90 - 264 V, 47 - 63 Hz
Networking featuresGigabit Ethernet
Compatible operating systemsWindows, Linux, VMware, Hyper-V
InternalNo
LED indicatorsHDD, Power, Power fail, Status
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)20 - 80 %
Power consumption (typical)25 W
Power supply unit (PSU) capacity600 W
Weight and Dimensions IconWeight and Dimensions
Weight29300 g