48 Planning: MD3200i Series Storage Array Terms and Concepts
The priority of each of these operations can be changed to address
performance requirements of the environment in which the operations are to
be executed.
NOTE: Setting a high priority level impacts storage array performance. It is not
advisable to set priority levels at the maximum level. Priority must also be assessed
in terms of impact to host server access and time to complete an operation. For
example, the longer a rebuild of a degraded virtual disk takes, the greater the risk
for secondary disk failure.
Virtual Disk Migration and Disk Roaming
Virtual disk migration is moving a virtual disk or a hot spare from one array to
another by detaching the physical disks and re-attaching them to the new
array. Disk roaming is moving a physical disk from one slot to another on the
same array.
Disk Migration
You can move virtual disks from one array to another without taking the
target array offline. However, the disk group being migrated must be offline
before your perform disk migration. If the disk group is not offline prior to
migration, the source array holding the physical and virtual disks within the
disk group marks them as missing. However, the disk groups themselves
migrate to the target array.
An array can import a virtual disk only if it is in an optimal state. You can
move virtual disks that are part of a disk group only if all members of the disk
group are being migrated. The virtual disks automatically become available
after the target array has finished importing all the disks in the disk group.
When you migrate a physical disk or a disk group from one MD3200i array to
another, the MD3200i array you migrate to, recognizes any data structures
and/or metadata you had in place on the migrating MD3200i array. However,
if you are migrating from any device other than a MD3200i Series storage
array, the MD3200i array does not recognize the migrating metadata and that
data is lost. In this case, MD3200i initializes the physical disks and mark
them as unconfigured capacity.
book.book Page 48 Saturday, September 24, 2011 9:06 AM

Table of Contents

Other manuals for Dell PowerVault MD3200i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerVault MD3200i and is the answer not in the manual?

Dell PowerVault MD3200i Specifications

General IconGeneral
HDD speed15000 RPM
RAID levels0, 1, 5, 6, 10
Storage drive capacity600 GB
Storage drive interfaceSerial Attached SCSI (SAS)
Maximum supported storage capacity115.2 TB
Number of storage drives installed12
InterfaceRJ-45, SAS, PS/2
Connector(s)4x RJ-45, 1x 6Gb SAS, 1x PS/2
Power supply typeAC
Dimensions (WxDxH)446.3 x 561 x 86.8 mm
Power requirements90 - 264 V, 47 - 63 Hz
Networking featuresGigabit Ethernet
Compatible operating systemsWindows, Linux, VMware, Hyper-V
InternalNo
LED indicatorsHDD, Power, Power fail, Status
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)20 - 80 %
Power consumption (typical)25 W
Power supply unit (PSU) capacity600 W
Weight and Dimensions IconWeight and Dimensions
Weight29300 g