Troubleshooting: Your Storage Array Software 253
19
If you have recently replaced or added the RAID controller module, restart
the host context agent software so that the new RAID controller module is
recognized.
20
If the problem still exists, make the appropriate host modifications, check
with other administrators to see if a firmware upgrade was performed on
the RAID controller module from another storage management station.
If a firmware upgrade was performed, the EMW on your management
station may not be able to locate the new AMW software needed to
manage the storage array with the new version of the firmware.
21
If the problem persists contact your Technical Support representative.
22
Determine if there is an excessive amount of network traffic to one or
more RAID controller modules.
This problem is self-correcting because the EMW software periodically
retries to establish communication with the RAID controller modules in
the storage array. If the storage array was unresponsive and a subsequent
try to connect to the storage array succeeds, the storage array becomes
responsive.
For an out-of-band managed storage array, determine if management
operations are taking place on the storage array from other storage
management stations. A RAID controller module-determined limit exists
to the number of Transmission Control Protocol/Internet Protocol
(TCP/IP) connections that can be made to the RAID controller module
before it stops responding to subsequent connection attempts. The type of
management operations being performed and the number of management
sessions taking place together determine the number of TCP/IP
connections made to a RAID controller module. This problem is self-
correcting because, after some TCP/IP connections terminate, the RAID
controller module then becomes responsive to other connection attempts.
23
If the storage array is still unresponsive, a problem may exists with the
RAID controller modules. Contact your Technical Support representative.
Locating a Physical Disk
You can use the Locate Physical Disk option to physically locate and identify
one or more of the physical disks in an expansion enclosure by activating
physical disk LEDs.
book.book Page 253 Saturday, September 24, 2011 9:06 AM

Table of Contents

Other manuals for Dell PowerVault MD3200i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerVault MD3200i and is the answer not in the manual?

Dell PowerVault MD3200i Specifications

General IconGeneral
HDD speed15000 RPM
RAID levels0, 1, 5, 6, 10
Storage drive capacity600 GB
Storage drive interfaceSerial Attached SCSI (SAS)
Maximum supported storage capacity115.2 TB
Number of storage drives installed12
InterfaceRJ-45, SAS, PS/2
Connector(s)4x RJ-45, 1x 6Gb SAS, 1x PS/2
Power supply typeAC
Dimensions (WxDxH)446.3 x 561 x 86.8 mm
Power requirements90 - 264 V, 47 - 63 Hz
Networking featuresGigabit Ethernet
Compatible operating systemsWindows, Linux, VMware, Hyper-V
InternalNo
LED indicatorsHDD, Power, Power fail, Status
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)20 - 80 %
Power consumption (typical)25 W
Power supply unit (PSU) capacity600 W
Weight and Dimensions IconWeight and Dimensions
Weight29300 g

Related product manuals