Serial port Configure Modbus mode
IX30 User Guide
249
17. Configure serial port logging:
a. Enable serial port logging:
(config)>path-paramenable true
(config)>
b. Set the size of the log file:
(config)>path-paramsize value
(config)>
where value is the size of the log file in bytes. The default is 65536.
The log file is saved to the /opt/serial directory. Because this is being save to the device's
memory, you should use serial logging for diagnostic purposes, rather than having it
permanently enabled.
18. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
19. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.
Configure Modbus mode
Modbus mode allows you to use the serial port for Modbus. See Modbus gateway.
To change the configuration to match the serial configuration of the device to which you want to
connect:
Web
1. Log into the IX30 WebUI as a user with Admin access.
2. On the menu, click System. Under Configuration, click Serial Configuration.
The Serial Configuration page is displayed.