Digital Input/Output and Analog Input Configure digital Input/Output ports
IX30 User Guide
827
Digital output
n
This output is an open-collector, sinking driver output.
n
The default state at power-up is off.
Specification Min Nom Max Units
Sink Current .. .. 200 mA
Pull-up Voltage 3.3 V
Analog input specifications
Specification Min Nom Max Units
Resolution .. .. 12 BITS
Accuracy .. .. 0.2 %
Rated Input Voltage -0.2 30 V
Rated Input Current 0 40 mA
Voltage input mode (default)
Specification Min Nom Max Units
Input Voltage -0.2 .. 10.5 V
Input Impedance .. 253K .. Ohms
Current loop mode
Specification Min Nom Max Units
Minimum Input Voltage .. 2 .. V
Load Resistance .. 200 .. Ohms
Configure digital Input/Output ports
Required configuration items
n
Whether the Input/Output pin should be handled as active low or active high.
n
The bias on the pin to enable pull-up/pull-down.
n
The direction of the pin, either Input or Output.