Table 3-7 SPMD 400V motor drive ratings (380V to 480V ±10%) based on AC supply voltage
*SPMD14X1 to 14X3 ratings apply with the rectifier docked and undocked.
**SPMD14X4 rating with the rectifier docked. The overload rating for the SPMD14X4 is only available if the ambient temperature is 35°C or lower.
***SPMD14X4 rating with the rectifier undocked. The maximum continuous output current and overload rating for the SPMD14X4 is only available if
the ambient temperature is 35°C or lower.
Table 3-8 Paralleled SPMD 400V motor drive ratings (380V to 480V ±10%) based on AC supply voltage
Table 3-9 SPMD 690V motor drive ratings (500V to 690V ±10%)
Model
Normal Duty Heavy Duty
Required
rectifier
Required
input line
reactor
External 24V
current
consumption
Maximum
continuous
output
current
Peak
current
Nominal
motor
power at
400V
Nominal
motor
power at
460V
Maximum
continuous
output
current
Open
loop
peak
current
Closed
loop
peak
current
Nominal
motor
power
at 400V
Nominal
motor
power at
460V
AAkWhp AAAkWhp
A
SPMD14X1* 205 225 110 150 180 232 270 90 150
1 x
SPMC1402
1 x INL401 3.3
SPMD14X2* 246 270 132 200 210 271 315 110 150
SPMD14X3* 290 319 160 250 246 310 359 132 200
1 x INL402 4.5SPMD14X4** 335 365 185 300 290 374 435 160 250
SPMD14X4***
350 385 200 300 290 374 435 160 250
Paralleled SPMD modules
Normal Duty Heavy Duty
Required
rectifier
Required
input line
reactor
Required
output
sharing
choke
Maximum
continuous
output
current
Peak
current
Nominal
motor
power at
400V
Nominal
motor
power at
460V
Maximum
continuous
output
current
Open
loop
peak
current
Closed
loop
peak
current
Nominal
motor
power
at 400V
Nominal
motor
power at
460V
AAkWhp A AAkWhp
2 x SPMD14X1 389 428 225 300 342 439 512 185 300
1 x SPMC2402
1 x INL411
1 x OTL411
2 x SPMD14X2 467 514 280 400 399 513 598 225 300 1 x OTL412
2 x SPMD14X3 551 606 315 450 467 586 683 280 400
1 x INL412
1 x OTL413
2 x SPMD14X4 636 700 355 500 551 708 826 315 450 1 x OTL414
3 x SPMD14X2 701 771 400 600 598 769 897 315 500
1 x SPMC2402 +
1 x SPMC1402
1 x INL411 +
1 x INL401
3 x OTL402
4 x SPMD14X1 779 856 450 650 684 878 1025 355 600 2 x SPMC2402 2 x INL411 4 x OTL401
3 x SPMD14X3 826 909 450 700 701 879 1025 400 650
1 x SPMC2402 +
1 x SPMC1402
1 x INL412 +
1 x INL402
3 x OTL403
4 x SPMD14X2 934 1028 500 800 798 1026 1197 450 700 2 x SPMC2402 2 x INL411 4 x OTL402
3 x SPMD14X4 954 1050 560 800 826 1062 1239 450 750
1 x SPMC1402 +
1 x SPMC2402
1 x INL412 +
1 x INL402
3 x OTL404
4 x SPMD14X3 1102 1212 630 900 934 1172 1367 550 800
2 x SPMC2402
2 x INL412 4 x OTL403
4 x SPMD14X4 1272 1400 710 1000 1102 1416 1652 630 900 2 x INL412 4 x OTL404
When connecting drives in parallel they must be derated. Table 3-2, Table 3-4, Table 3-6, Table 3-8 and Table 3-10 have already the
required de-rating.
NOTE
Model
Normal Duty Heavy Duty
Required
rectifier
Required
input line
reactor
External 24V
current
consumption
Maximum
continuous
output
current
Peak
current
Nominal
motor
power
at 690V
Nominal
motor
power
at 575V
Maximum
continuous
output
current
Open
loop
peak
current
Closed
loop
peak
current
Nominal
motor
power
at 690V
Nominal
motor
power
at 575V
AAkW
hp
AAAkW
hp A
SPMD16X1 125 137 110 125 100 129 150 90 100
1 x
SPMC/U1601
1 x INL601 3.3
SPMD16X2 144 158 132 150 125 161 188 110 125
SPMD16X3 168 184 160 150 144 185 216 132 150
1 x INL602 4.5
SPMD16X4 192 211 160 200 168 216 252 150 150