16. RADAR OVERLAY
16-7
16.4 Error Between Radar Echo Image and Chart
There are several reasons why the radar echo image and chart display do not match
exactly. The mismatch is a combination of several reasons and removing one reason
doesn't solve the mismatch perfectly. There is a fundamental difference between the
radar echo image and corresponding chart feature. The radar echo is a reflection from
the real life target and the actual position of the real life target is the front edge of the
radar echo. Therefore, the radar echo should start from the chart feature and exist as
far as the radar pulse length goes.
How to compensate for bearing error
Bearing error occurs in the following instances:
• Gyro error
• Inaccurate chart
• Improper installation parameters (radar overlay bearing offset)
How to compensate for position error
Position is caused by the following:
• Inaccurate position
• Position offset
• Inaccurate chart
• Improper installation parameters (conning position offset, position receiver antenna
offset, radar overlay range offset)

Table of Contents

Other manuals for Furuno FMD-3200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FMD-3200 and is the answer not in the manual?

Furuno FMD-3200 Specifications

General IconGeneral
BrandFuruno
ModelFMD-3200
CategoryMarine Equipment
LanguageEnglish

Related product manuals