25. ALERT MANAGEMENT SYSTEM (option)
25-8
25.7 How an Alarm is Transferred to the BNWAS
Alarms are transferred to the BNWAS in the following sequence.
Note: For a DNV class vessel, only category A Alarms are transferred.
1) An Alarm generated by an equipment connected to the AMS is transferred to the
BNWAS if it is not acknowledged within 30 seconds.
2) The BNWAS sends the Emergency Call to applicable Cabin Panels in living quar-
ters and general quarters, to inform personnel of an unacknowledged Alarm.
To stop both the Emergency Call and the transfer of the Alarm, do as follows:
• Category A, Category C Alarm: Acknowledge the alert at the equipment that gen-
erated the Alarm.
• Category B Alarm: Acknowledge the alert at the equipment that generated the
Alarm or the AMS.
Note: The transfer of Alarms can be stopped (when in port, etc.) by setting the system
in Silent mode. See section 1.4 for details.
AMS
Alarm generated.
BNWAS
Cabin
Panel
Alarm is transferred if not
acknowledged within 30
seconds.
Cabin
Panel
Cabin
Panel
Cabin
Panel
Cabin
Panel
Connected
equipment
Emergency Call sent to Cabin Panels.

Table of Contents

Other manuals for Furuno FMD-3200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FMD-3200 and is the answer not in the manual?

Furuno FMD-3200 Specifications

General IconGeneral
BrandFuruno
ModelFMD-3200
CategoryMarine Equipment
LanguageEnglish

Related product manuals