25. ALERT MANAGEMENT SYSTEM (option)
25-6
HBT sentence
Both external equipment and the AMS output the HBT sentence periodically to confirm
normal operation between each other. The sentence is output regardless of whether
an alert is generated or not.
When the HBT sentence is not received within the interval set, an appropriate alert is
generated which announces equipment trouble (power off, etc.). The AMS generates
the alert “Loss of system communication”.
When an alert is generated...
When an alert condition is found at an external equipment, the equipment sends the
ALF sentence to the AMS.
The ALF sentence contains Alert ID, Alert Priority, Alert Category, ACK/Silence, and
other information. The AMS generates an alert based on the ALF sentence and sends
it to the external equipment to acknowledge receipt of the alert.
Periodic transmission
External equipment periodically (30 s or less) send alert status to the AMS using the
ALC sentence.
If the ALC sentence contains an alert, the AMS sends the ACN sentence to the exter-
nal equipment to request re-notification.
AMS
HBT
External
Equipment
HBT
External
Equipment
AMS
ALF
External
Equipment
External
Equipment
Generate alert
based on ALF
sentence
Alert
condition
Generate
alert
AMS
ALC
External
Equipment
External
Equipment
Confirm no
omission of
sentences
Alert(s)
activated
(ACN)

Table of Contents

Other manuals for Furuno FMD-3200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FMD-3200 and is the answer not in the manual?

Furuno FMD-3200 Specifications

General IconGeneral
BrandFuruno
ModelFMD-3200
CategoryMarine Equipment
LanguageEnglish

Related product manuals