IDPS Command Differences
Sense Type and Model
Only the modified command set vector tables are described here. The changes
are:
•
Device and Model
•
Loaded Font Command set vector (LF2 support) is not reported in the STM.
Table 109. Sense Type and Model
Special Data
Area
Value Description
Byte 0 X'FF' System/370 convention
Bytes 1-2 X'64xx' PRODUCT CODE
Byte 3 X'01' MODEL CTA
Bytes 4-5 X'0000' Reserved
XOH OPC Printable Area SDF
Table 110. Printable Area
Special Data
Area
Value Description
Bytes 0-1 X'0018' LENGTH of this Self Defining Field
Bytes 2-3 X'0001' PRINTABLE AREA Self Defining Field ID
Byte 4 X'00' DEFAULT INPUT MEDIA SOURCE
Byte 5 X'00' Reserved
Byte 6 X'00' UNIT BASE 10 inches
Byte 7 X'00' Reserved
Bytes 8-9 X'3840' L-units per UNIT BASE
Bytes 10-11 X'13B0' - X'4C80' WIDTH of the physical medium in L-units
(+Xm direction) Does NOT include
width of carrier strip for continuous
forms media.
Bytes 12-13 X'000A' - X'7FFF' LENGTH of the physical medium in
L-units (+Ym direction)
Bytes 14-15 X'0000' Xm OFFSET of the Printable Area in
L-units
Bytes 16-17 X'0000' Ym OFFSET of the Printable Area in
L-units All Forms Devices
Bytes 18-19 X'13B0' - X'4A40' Xm EXTENT of the Printable Area in
L-units
Bytes 20-21 X'000A' - X'7FFF' Ym EXTENT of the Printable Area in
L-units
Bytes 22-23 Bit 0 0
Bit 1 01
Bit 2 01
Bit 3 1
Bit 4 0
Bit 5 0
Bit 6 0
Bits 7-15 000000000
INPUT MEDIA SOURCE CHARACTERISTICS
0 = Simplex
01 = Continuous Forms
1 = Bin Available
0 = Retired
0 = No Envelopes
0 = Auto Media Feed
Reserved
136 6400 IPDS