Equipment Check — X'10'
The following exception codes are the valid codes for an equipment check
condition and apply only to coax attachments:
X'10F100' Permanent Error
Explanation:
1. There was a permanent hardware error.
2. The microcode detected an unrecoverable logic error.
3. The microcode detected a condition that should not have occurred.
Alte rn a te Ex c e p tion Actio n : None.
Data Check — X'08'
The following exception codes are the valid codes for a data check condition:
X'082100' Undefined Character
Explanation:
1. An undefined character code has been detected in Write Text data.
2. An undefined overstrike character code has been detected.
3. A character has been detected in Write Text Command data which is
undefined at the quality level specified by the XOA-PQC command.
4. An undefined character code has been detected in Write Bar Code data.
Alte rn a te Ex c e p tion Actio n : For reasons 1-3, print the default character. For
reason 4, there is no alternate exception action.
Appendix A. IPDS Exception Reporting Codes 141