Presentation Text Command Set
Table 59. Relative Move Inline
Byte Value Description Error Code
0-1 X'2BD3' Text Control Escape Sequence
2 X'04' Length X'021E..01'
3
X'C8'
X'C9'
Relative Move Inline
Unchained
Chained
4-5 X'8000' -X'7FFF' Increment (Ir) See “Notation Conventions” on
page 27
Repeat String (RPS)
This control contains a string of coded graphic characters that repeats on the
current line. The data field can be a maximum of 253 bytes. The printer does
not check the data for the control sequence introducer (X
'2B'). If the repeat
length is zero, this control is a no-op. If the count equals 04, but the repeat
length is greater than zero, an error occurs.
Table 60. Repeat String
Byte Value Description Error Code
0-1 X'2BD3' Text Control Escape Sequence
2 X'04' -X'FF' Length X'021E..01'
3
X'EE'
X'EF'
Repeat String
Unchained
Chained
4-5 X'0000' -X'7FFF' Repeat Length (RL) X0219..01'
6-n Repeat Data X021F..01'
Set Baseline Increment (SBI)
This control specifies a distance which the printer adds to the current baseline
coordinate when the printer performs a Begin Line control. A value of X
'FFFF'
causes the printer to use the value in the LPD command.
Table 61. Set Baseline Increment
Byte Value Description Error Code
0-1 X'2BD3' Text Control Escape Sequence
2 X'04' Length X'021E..01'
3
X'D0'
X'D1'
Set Baseline Increment
Unchained
Chained
4-5 X'8000' -X'7FFF'
X'FFFF'
Increment (Bi)
See “Notation Conventions” on page 27
Use LPD value or, if no LPD
received, use printer default
70 6400 IPDS