lldp-med {
interface all;
}
rstp;
}
ethernet-switching-options {
storm-control {
interface all;
}
}
poe {
interface all;
}
Related
Documentation
Reverting to the Default Factory Configuration for the EX Series Switch•
• Connecting and Configuring an EX Series Switch (CLI Procedure) on page 165
• Connecting and Configuring an EX Series Switch (J-Web Procedure) on page 168
• Understanding Configuration Files for EX Series Switches
• EX Series Switches Interfaces Overview
Connecting and Configuring an EX Series Switch (CLI Procedure)
There are two ways to connect and configure an EX Series switch: one method is through
the console by using the CLI and the other is by using the J-Web interface.
NOTE: EX2200-24T-4G-DC switches do not support switch connection and
configuration through the J-Web interface.
This topic describes the CLI procedure.
NOTE: To run the ezsetup script, the switch must have the factory-default
configuration as the active configuration. If you have configured anything on
the switch and wanttorun ezsetup, revert to the factory-default configuration.
See Reverting to the Default Factory Configuration for the EX Series Switch.
Using the CLI, set the following parameter values in the console server or PC:
•
Baud rate—9600
•
Flow control—None
•
Data—8
•
Parity—None
165Copyright © 2017, Juniper Networks, Inc.
Chapter 15: Performing Initial Configuration