NOTE: The weight of an EX4200 switch with one power supply installed is
between 16–18 lb (7.2–8.2 kg).
Related
Documentation
Rack Requirements on page 68•
• Cabinet Requirements on page 68
• Mounting an EX4200 Switch on page 128
• Installing and Connecting an EX4200 Switch on page 127
• Installing and Removing EX4200 Switch Hardware Components on page 140
Field-Replaceable Units in EX4200 Switches
Field-replaceable units (FRUs) are components that you can replace at your site. The
FRUs in the switch are:
•
Power supply
•
Fan tray
•
Uplink module
•
Transceivers
NOTE: Uplink modules are not part of the standard package and must be
ordered separately.
The fan tray, uplink module, and transceivers are hot-removable and hot-insertable: You
can remove and replace them without powering off the switch or disrupting switch
functions.
NOTE: If you have a Juniper J-Care service contract, register any addition,
change, or upgrade of hardware components at
https://www.juniper.net/customers/support/tools/updateinstallbase/ . Failure
to do so can result in significant delays if you need replacement parts. This
note does not apply if you replace existing components with the same type
of component.
Related
Documentation
Installing an Uplink Module in an EX4200 Switch on page 187•
• Installing a Power Supply in an EX4200 Switch on page 183
• Removing a Power Supply from an EX4200 Switch on page 185
• Installing a Fan Tray in an EX4200 Switch on page 179
Copyright © 2017, Juniper Networks, Inc.10
EX4200 Switch Hardware Guide