Table 42: Site Electrical Wiring Guidelines for the Services Gateway
GuidelineSite Wiring Factor
To ensure that signaling functions optimally:
Install wires correctly.
Improperly installed wires can emit radio interference.
Do not exceed the recommended distances or pass wires
between buildings.
The potential for damage from lightning strikes increases if wires
exceed recommended distances or if wires pass between
buildings.
Shield all conductors.
The electromagnetic pulse (EMP) caused by lightning can
damage unshielded conductors and destroy electronic devices.
Signaling Limitations
To reduce or eliminate the emission of RFI from your site wiring:
Use twisted-pair cable with a good distribution of grounding
conductors.
Use a high-quality twisted-pair cable with one ground conductor
for each data signal when applicable, if you must exceed the
recommended distances.
Radio Frequency
Interference (RFI)
Provide a properly grounded and shielded environment and use
electrical surge-suppression devices.
Strong sources of electromagnetic interference (EMI) can cause
the following damage:
Destroy the signal drivers and receivers in the device
Conduct power surges over the lines into the equipment, resulting
in an electrical hazard
NOTE: If your site is susceptible to problems with EMC, particularly
from lightning or radio transmitters, you may want to seek expert
advice.
Electromagnetic
Compatibility (EMC)
CAUTION: To comply with intrabuilding lightning/surge requirements, the
intrabuilding wiring must be shielded. The shielding for the wiring must be
grounded at both ends.
Related
Documentation
General Site Guidelines for Installing the SRX110 Services Gateway on page 40
SRX110 Services Gateway Power Specifications and Requirements on page 132
SRX110 Services Gateway Power Specifications and Requirements
The AC power system electrical specifications for the SRX110 Services Gateway are listed
in Table 43 on page 133.
Copyright © 2013, Juniper Networks, Inc.132
SRX110 Services Gateway Hardware Guide

Table of Contents

Other manuals for Juniper SRX110

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper SRX110 and is the answer not in the manual?

Juniper SRX110 Specifications

General IconGeneral
BrandJuniper
ModelSRX110
CategoryGateway
LanguageEnglish

Related product manuals