Powering On and Powering Off the SRX110 Services Gateway
This topic includes the following sections:
Powering On the SRX110 Services Gateway on page 71
Powering Off the SRX110 Services Gateway on page 71
Resetting the SRX110 Services Gateway on page 72
Powering On the SRX110 Services Gateway
To power on the services gateway:
1. Ensure that you have connected the power supply to the device.
2. Insert the plug of the power supply adapter into an AC power source receptacle.
3. Turn on the power to the services gateway.
The device starts automatically as the power supply completes its startup sequence.
The Power LED lights up during startup and remains on when the device is operating
normally.
NOTE: After the power supply is turned on, it can take up to 60 seconds for
status indicators—such as the Status and Power LEDs—to show that the
power supply is functioning normally.
NOTE: We recommend you issue the CLI command request system power-off
when you want to power off the device immediately after powering it on.
Powering Off the SRX110 Services Gateway
You can power off the services gateway in one of two ways:
Graceful shutdown Press and release the Power button. The device begins gracefully
shutting down the operating system and then powers itself off.
Forced shutdown Press the Power button and hold it for more than 10 seconds. The
device immediately powers itself off without shutting down the operating system.
NOTE: Do not press the Power button while the device is shutting down.
CAUTION: Use the graceful shutdown method to halt, power off, or reboot
the services gateway. Use the forced shutdown method as a last resort to
recover the services gateway if the services gateway operating system is not
responding to the graceful shutdown method.
71Copyright © 2013, Juniper Networks, Inc.
Chapter 11: Connecting, Grounding, and Powering On the SRX110 Services Gateway

Table of Contents

Other manuals for Juniper SRX110

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper SRX110 and is the answer not in the manual?

Juniper SRX110 Specifications

General IconGeneral
BrandJuniper
ModelSRX110
CategoryGateway
LanguageEnglish

Related product manuals