Technical data
3-7
 SHB9300CRV EN 2.0
3.3.5 Mains filter
Type
Rated data (uk
îš
6%) Lenze order number
Mains current Inductance for RFI degree A for RFI degree B
9321 1.5 A 24 mH EZN3A2400H002 EZN3B2400H002
9322 2.5 A 15 mH EZN3A1500H003 EZN3B1500H003
9323 4A 9mH EZN3A0900H004 EZN3B0900H004
9324 7A 5mH EZN3A0500H007 EZN3B0500H007
9325 13 A 3mH EZN3A0300H013 EZN3B0300H013
9326 24 A 1.5 mH EZN3A0150H024 EZN3B0150H024
9327 30 A 1.1 mH EZN3A0110H030 EZN3B0110H030
9328 42 A 0.8 mH EZN3A0080H042 EZN3B0080H042
9329 60 A 0.54 mH EZN3A0055H060 EZN3B0055H060
9330 90 A 0.37 mH EZN3A0037H090 EZN3B0037H090
9331 150 A 0.22 mH EZN3A0022H150 EZN3B0022H150
9332 150 A 0.22 mH EZN3A0022H150 EZN3B0022H150
The mains filters for RFI degree B contain additional RFI suppression components.
3.4 Dimensions
The dimensions of the controllers depend on the mechanical installation. (
&
4-1)