EasyManuals Logo

Lenze i510 User Manual

Lenze i510
127 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #64 background imageLoading...
Page #64 background image
6 Function & parameter description
Group 3 Motor control
64 Lenze · Inverter i510 / i550 - Cabinet · Operation Manual · 0.4 EN · 02/2016
6.5.11 Skip frequency
Three skip frequencies are available to lock out critical frequencies that cause mechanical resonance.
Example:
Skip frequency 20 Hz
Skip bandwidth 10 Hz
Frequency area 15 Hz .. 25 Hz is skipped
i
Fig. 19: Skip frequency
P317:1
0x291F:1
Skip frequency 1
i510
i550
R/W
0.0 ... [0.0] ... 599.0 Hz
Skip frequency 1
P317:2
0x291F:2
Skip bandwidth 1
i510
i550
R/W
0.0 ... [0.0] ... 10.0 Hz
Skip bandwidth 1
P317:3
0x291F:3
Skip frequency 2
i510
i550
R/W
0.0 ... [0.0] ... 599.0 Hz
Skip frequency 2
P317:4
0x291F:4
Skip bandwidth 2
i510
i550
R/W
0.0 ... [0.0] ... 10.0 Hz
Skip bandwidth 2
P317:5
0x291F:5
Skip frequency 3
i510
i550
R/W
0.0 ... [0.0] ... 599.0 Hz
Skip frequency 3
P317:6
0x291F:6
Skip bandwidth 3
i510
i550
R/W
0.0 ... [0.0] ... 10.0 Hz
Skip bandwidth 3

Table of Contents

Other manuals for Lenze i510

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i510 and is the answer not in the manual?

Lenze i510 Specifications

General IconGeneral
Product CategoryDC Drives
Seriesi510
Protection ClassIP20
CommunicationCANopen, Modbus RTU
Protection FeaturesOvervoltage, Undervoltage
Operating Temperature-10 to +50 °C
Storage Temperature-25 to +70 °C
Humidity5% to 95% (non-condensing)
Control ModeV/f control

Related product manuals