6 Function & parameter description
Group 3 – Motor control
68 Lenze · Inverter i510 / i550 - Cabinet · Operation Manual · 0.4 EN · 02/2016
6.5.17 Overspeed monitoring
The inverter contains Motor Overspeed detection. If the specified threshold is exceeded, the inverter will react as
defined.
The overspeed monitoring is only active if the motor is in motoring mode.
50 ... [8000] ... 50000 rpm
3:Fault
(Reference see P310:1)
6.5.18 Overcurrent monitoring
The inverter monitors the output current and compares it to a threshold value. If the specified threshold is ex-
ceeded, the inverter will react as defined.
This parameter can also be set and overwritten by selecting a Motor from the catalog or by using the
non-energized calibration process. The user should adjust this default value for proper protection.
0.0 ... [Type Code dependent] ...
1000.0 A
3:Fault
(Reference see P310:1)
Overcurrent fault reaction