Power supply modules
Rated data
Operation at rated mains voltage 230 V
5
243
EDS94SPP101 EN 10.2
5.3.2 Operation at rated mains voltage 230 V
Input data
Mains Voltage Voltage range Frequency range
U
Lrated
[V] U
Lrated
[V] f [Hz]
3/PE AC 230 180 − 0 % ... 264 + 0 % 45 − 0 % ... 65 + 0 %
Voltage Continuous input power
Type [V] S
L
[kVA]
E94APNE0104 230 3.2
E94APNE0364 230 11.5
E94APNE1004 230 32.6
E94APNE2454 230 79.6
Output data
Mains Volta
g
e Volta
g
e ran
g
e Fre
q
uenc
y
ran
g
e
Voltage
U
DC
[V]
Voltage
range
U
DC
[V]
Frequency
range
f [Hz]
2/PE DC 325 260 − 0 % ... 370 + 0 %
Output current and output power
100 % 5−s cycle 3−min cycle
Type I
DC
[A] P
DC
[kW] I
DC
[A] P
DC
[kW] I
DC
[A] P
DC
[kW]
E94APNE0104 10 2.1 40 8.4 15 3.2
E94APNE0104
+ E94AZMP0084
10 2.8 40 11.2 15 4.2
E94APNE0364 36 7.5 108 22.5 54 11.3
E94APNE0364
+ E94AZMP0294
36 10.1 108 30.3 54 15.5
E94APNE1004 100 20.8 200 41.6 150 31.2
E94APNE1004
+ E94AZMP0824
100 27.9 200 55.8 150 41.9
E94APNE2454 245 51 368 76.5 368 76.5
E94APNE2454
+ E94AZMP2004
245 68.5 368 103 368 103
100 % Permanent rated values
5−s cycle Cycle for the second−range
(0.5 s overload/4.5 s recovery time with 75 % of the permanent rated value)
3−min cycle Cycle for the minute−range
(60 s overload/120 s recovery time with 75 % of the permanent rated value)

Table of Contents

Other manuals for Lenze L-force 9400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze L-force 9400 and is the answer not in the manual?

Lenze L-force 9400 Specifications

General IconGeneral
BrandLenze
ModelL-force 9400
CategoryDC Drives
LanguageEnglish

Related product manuals